FLAME SCANNERS AND APPLICATIONS
 

The following Fireye flame scanners are used in conjunction with the appropriate Fireye flame safeguard controls to provide reliable flame detection on a variety of burner applications and fuel types.

UVIA
Bulletin SC-102
Ultraviolet miniature non self-checking scanners. The UV1A is suitable for fuel gases and no. 2 oil. Non-replaceable tube. Mounting collar 1/2" NPT. Available with 3 ft (UV1A3), 6 ft. (UV1A6), or 50 ft. (UV1A50) of flexible conduit. Explosion proof housings are available.

 

UV90
Bulletin SC-102
Ultraviolet miniature non self-checking scanner suitable for frontal or side (90°) viewing. Complete with mounting fixture. Available with 3 ft (UV90-3), 6 ft. (UV90-6), or 9 ft. (UV90-9) of flexible conduit.

 

UV2
Bulletin SC-102
Ultraviolet miniature non self-checking scanner. Similar in function to the UV1A3 but with a smaller mounting collar (3/8"). Non-replaceable tube.

 

UV8A
Bulletin SC-102
A 90× version of the UV1A6, but with unshielded leads and 0.70" diameter collar to be used with a 1/2" E.M.T rain tight fitting (not furnished). The mounting collar is 1/2" NPT. Must be installed with metal shielding over the scanner leads.

 

45UV5-1005, -1006, -1007, -1008, -1009
Bulletin SC-101
Self-checking ultraviolet scanner is for continuously fired applications where recycling is infrequent or absent. The self-checking circuit checks the electronics and the UV tube for proper operation every four seconds during the firing period. Suitable for fuel gases and oil. Replaceable UV tube and (4-314-1) shutter mechanism (61-2914). Mounting 1" NPT or BSP pipe thread with 8 ft. (2.4m) lead wires. Must be installed with metal shielding over the scanner leads. Explosion-proof housings are available for models 45UV5-1007 and 45UV5-1009.

 

45UV3-1050
Bulletin SC-102
A rugged diecast housing that mounts on 3/4 inch pipe with setscrew. Vertical mounting of UV tube provides greater sensitivity. UV tube is replaceable (4-314-1). Scanner is non self-checking. 4 ft (1200mm) lead wires. Must be installed with metal shielding over this canner leads.

 

69ND1
Bulletin SC-103
Flame rod for gas flames only. The flame rod is an inexpensive reliable gas flame detector. Mounting 1/2" male NPT. 12" (304mm), 18" (475mm), and 24" (609mm) available.

 

45CM1
Bulletin SC-103
Photocell scanner with #922 photocell and Rajah stud terminal is designed for use in the blast tube on conventional pressure atomizing oil burners. Available with or without a filter.

 

48PT2
Bulletin SC-103
Lead sulfide infrared scanner is designed to detect low frequency IR signals from gas or oil flames. Mounting collar is 1/2" NPT with straight or 90× mounts (shown). Available with 4 ft (121.9m) or 8 ft (243.8m) flexible conduit. Replaceable 4-263-1 sensor cell.

 

48PT1
Bulletin SC-103
Lead sulfide infrared detector is identical in size and function to the 48PT2 but is used with the older-style P-Series controls (e.g. 26RJ8, 29RF5 controls). The mounting collar is 1/2" NPT. Replaceable 4-128-1 sensor cell. Available with 4 ft. (122) or 8 ft. (244) flexible conduit.

 


 
PART NUMBER
DESCRIPTION
USE WITH
BULLETIN
Ultraviolet Scanners
UV1A-1-CEX Cenelec EExd IIC explosion-proof housing with UV1A scanner.
Flame -Monitor,
FlameWorx, MB,
C-Series,
D-Series,
M-Series, M-II Series,
MicroM Series with non-self check amplifier.
UV1A3 1/2" NPT Connector, 3 ft. (914mm) flexible cable. Non self-checking.
UV1A6 1/2" NPT Connector, 6 ft. (1828mm) flexible cable. Non self-checking.
UV1A50 1/2" NPT Connector, 50 ft. flexible cable.Non self-checking.
UV2 3/8" NPT Connector, 3 ft. (914mm) flexible cable. Non self-checking.
UV8A 1/2" NPT 90× head, 6 ft. wire, no cable. Non self-checking.
UV90-3 UV non-self check scanner for frontal or side (90°) viewing. Complete with mounting fixture and 3 ft. (900mm) flex conduit.
UV90-6 UV non-self check scanner for frontal or side (90°) viewing. Complete with mounting fixture and 6 ft. (1800mm) flex conduit.
UV90-9 UV non-self check scanner for frontal or side (90°) viewing. Complete with mounting fixture and 9 ft. (2700mm) flex conduit.
45UV3-1050 UV Scanner, 3/4" sleeve/set screw mounting. Non self-checking. 25RU8 only
45UV2-1020 UV Scanner, 1 inch NPT mount, 60 Hz. Non self-checking. 25RU8 only
45UV5-1005 UV self-check scanner 1 inch NPT threads. 25VDC shutter circuit. 25RU8-4580,
25SU5-4018
45UV5-1105 Same as -1005 but British threads. 25RU8-4580,
25SU5-4018
45UV5-1006 UV self-check scanner. Use with self-check amplifier only, 1 inch NPT threads. D-Series,
72DUVS1 only
45UV5-1007 UV self-check scanner. Use with self-check amplifier. 1 inch British threads, 230 VAC shutter.
Flame-Monitor,
C-Series,
D-Series, MicroM Series
with self-check amplifier.
45UV5-1007CEX Cenelec EExd IIC explosion proof housing with 45UV5-1007 scanner.
45UV5-1008 UV self-check scanner. Use with self-check amplifier. 1 inch British threads, 120 VAC shutter.
45UV5-1009 UV self-check scanner. Use with self-check amplifier. 1 inch NPT threads, 120 VAC shutter.
45UV-1009CEX EExd explosion proof housing with 45UV5-1009 scanner.
45UV5-1009EX Explosion proof 45UV5-1009. Class I, Div. 1 and 2, Groups C and D.
Class 2 Div. 1 and 2, Groups E, F, G.
Infared Scanners
48PT1-1003 IR Scanner, 8 ft. (2400mm) shielded cable, straight head
P-Series
48PT1-1007 IR Scanner, 4 ft. (1200mm) shielded cable, straight head
48PT1-9003 48PT1-1003, 8 ft. shielded cable with 90× head
48PT1-9007 48PT1-1007, 4 ft. shielded cable with 90× head
48PT1-9007W 48PT1-9007, 4 ft. shielded cable, water repellent with 90× head
48PT2-CEX Cenelec EExd IIC explosion proof housing with 48PT2 scanner
Flame-Monitor,
C-Series,
D-Series, MicroM Series
with infrared amplifier.
48PT2-1003 IR Scanner, 8 ft. (2400mm) shielded cable, straight head
48PT2-1007 IR Scanner, 4 foot (1200mm) shielded cable, straight head
48PT2-9003 48PT2-1003, 8 ft. shielded cable with 90× head
48PT2-9007 48PT2-1007, 4 ft. shielded cable with 90× head
48PT2-9007W 48PT2-9007, 4 ft. shielded cable, water repellent with 90° head
69ND1-1000K4 Flame Rod 12 inches 1/2" mount
Flame -Monitor,
FlameWorx, MB,
C-Series,
D-Series,
M-Series,
M-II Series,
MicroM Series with flame rectification amplifier.
69ND1-1000K6 Flame Rod 18 inches 1/2" mount
69ND1-1000K8 Flame Rod 24 inches 1/2" mount
45CM1-1000 Photocell scanner without filter
45CM1-1000Y Photocell scanner with filter