Cross Reference Table
Notes are referenced at the end of the table.
OBSOLETE
TYPE AND MODEL
NOTES
CURRENT MODEL COMBINATIONS
UP-GRADE KIT
CONTROL
DISPLAY
PROGRAMMER
AMPLIFIER
24CJ5-3000
1, 2, 3, 4
N/A
E110
ED510
EP380
ERT1
24CJ5-3010
1, 2, 3, 4
N/A
24CJ5-3011
1, 2, 3, 4
N/A
24CJ5-5010
2, 3, 4, 26
N/A
25CJ5-5011
2, 3, 4, 26
N/A
E110
ED510
EP390
ERT1
24CJ5-5015
2, 4,
N/A
E110
ED510
EP380
ERT1
24RJ8-1000
1, 2, 4
N/A
25CU6-1050
1, 2, 3, 4
N/A
E110
ED510
EP380
EUV1
25CU6-1062
1, 2, 3, 4, 26
N/A
25CU6-5062
2, 3, 4, 26
N/A
25CU6-1063
1, 2, 3, 4, 26
N/A
E110
ED510
EP390
EUV1
25CU6-5063
2, 3, 4, 26
N/A
25CU6-5065
2, 4,
N/A
E110
ED510
EP160
EUV1
25CU6-5066
2, 4,
N/A
E110
ED510
EP260
EUV1
25CU6-RS-2
1, 2, 3, 4
N/A
E110
ED510
EP380
EUV1
25CU6-RS-2D
1, 2, 3, 4
N/A
25CU6-RS-2RE
2, 3, 4,
N/A
E110
ED510
EP390
EUV1
25DU4-1040
1, 2, 6
N/A
70D40
--
--
72DUV1
25DU4-5040
2, 6
N/A
25DU4-5060
2
N/A
25RU8-4580
27
N/A
E110
ED510
EP160
EUVS4
25RU8-6558
7
PFM2-UV
E110
ED510
EP260
EUVS4
25RU8-6560
7
25RU8-6566
1, 4, 7, 8
N/A
E110
ED510
EP260
EUV1
25RU8-6570
7
PFM3-UV
E110
ED510
EP160
EUV1
25RU8-6580
1, 4, 7, 9
N/A
E110
ED510
EP260
EUV1
25SU5-1000
10, 11, 12
N/A
25SU5-5011
or
25SU5-5012
60-2205
(Optional)
--
INC.
25SU5-1011
10, 11, 12
N/A
25SU5-4011
11, 12
N/A
25SU5-4111
11, 12
N/A
25SU5-4013
13
N/A
70D40
--
--
72UVS4
25SU5-4018
13
N/A
26DF4-5030
2
N/A
70D40
--
--
72D1R1
26CF6-1000
1, 2, 3, 4
N/A
E110
ED510
EP380
E1R1
26CF6-1010
1, 2, 3, 4
N/A
26CF6-5020
2, 3, 4, 26
N/A
26CF6-1011
1, 2, 3, 4
N/A
E110
ED510
EP390
E1R1
26CF6-5021
2, 3, 4, 26
N/A
26CF6-5022
2, 4
N/A
E110
ED510
EP160
E1R1
26CF6-5022(A)
2, 4
N/A
26CF6-5023
2, 4
N/A
E110
ED510
EP260
E1R1
26CF6-RC-3A
1, 2, 3, 4
N/A
26RJ8-CB-1
14
PFM-9
E110
ED510
EP260
E1R1
26RJ8-CB-3
14
PFM-10
E110
ED510
EP160
E1R1
26RJ8-1000
14, 15, 16
PFM-1
E110
ED510
EP260
E1R1
26RJ8-1001
14, 15, 16
PFM-1
26RJ8-1002
14, 15, 16
PFM-1
26RJ8-1003
14, 15, 16
PFM-1
26RJ8-1004
14, 15, 16
PFM-1
26RJ8-1006
14, 15, 16
PFM-1
26RJ8-1008
14, 15, 16
PFM-1
26RJ8-1011
14, 15, 16
PFM-1
26RJ8-1012
14, 15, 16, 17
PFM-1
26RJ8-1016
14, 15, 16, 17
PFM-1
26RJ8-1018
14, 15, 16, 17
PFM-1
26RJ8-6008
14, 15, 16, 17
PFM-1
26RJ8-6012
14, 15, 16, 17
PFM-1
26RJ8-6016
14, 15, 16, 17
PFM-1
26RJ8-6018
14, 15, 16
PFM-1
26RJ8-1005
15, 18
N/A
E110
ED510
EP160
E1R1
26RJ8-1009
15, 18, 19
N/A
26RJ8-6009
15, 18, 19
N/A
26RJ8-1114
CONSULT FACTORY
26RJ8-1115
CONSULT FACTORY
26RJ8-5914
CONSULT FACTORY
26RJ8-6026
7, 18, 22
N/A
E110
ED510
EP260
E1R1
26RJ8-6058
14
PFM-2
E110
ED510
EP260
E1R1
26RJ8-6060
26RJ8-6066
26RJ8-6068
26RJ8-6010D
26RJ8-6070
14
PFM-3
E110
ED510
EP160
E1R1
26RJ8-6080D
14
PFM-10
E110
ED510
EP160
E1R1
26SJ5-1000
14, 15, 20
PD4
70D40
--
--
72D1R1
26SJ5-1102
26SJ5-5900T
26SJ5-5901T
26SJ5-5903
26SJ5-6000
26SJ5-6002
26SJ5-1150
14, 15, 20, 21
N/A
70D40
--
--
72D1R1 or
72DRT1
26SJ5-1152
26SJ5-6052
26SJ5-6152
26SJ5-5910
CONSULT FACTORY
29RF5-1000
14, 15
PFM-1
E110
ED510
EP260
E1R1
29RF5-1001
29RF5-1002
29RF5-1005
29RF5-1009
29RF5-1015
29RF5-1103
29RF5-6009
29RF5-6015
29RF5-6103
M-SERIES TO M-SERIES II TO MICROM CROSS REFERENCE LISTING
M-SERIES
M-SERIES II REPLACEMENT MODULES
MicroM REPLACEMENT MODULES
Part Number
Chassis
Amplifier
Programmer
Programmer
Dipswitch #8
Chassis
Amplifier
Programmer
Programmer
Dipswitch #6
UVM1D
MC120
MAUV1T
MP100
N/A
MEC120
MEUV1
MEP100
N/A
UVM1F
MC120
MAUVI
MP100
N/A
MEC120
MEUV4
MEP100
N/A
TFM1D
MC120
MART1T
MP100
See Note #A
MEC120
MERT1
MEP100
N/A
TFM1F
MC120
MART1
MP100
See Note #A
MEC120
MERT4
MEP100
N/A
UVM2
MC120
MAUV1
MP230
OFF
MEC120
MEUV4
MEP230
C
TFM2
MC120
MART1
MP230
OFF
MEC120
MERT4
MEP230
C
UVM3
MC120
MAUV1
MP230
ON
MEC120
MEUV4
MEP230
O
TFM3
MC120
MART1
MP230
ON
MEC120
MERT4
MEP230
O
UVM3H
MC120
MAUV1
MP230H
ON
MEC120
MEUV4
MEP230H
O
TFM3H
MC120
MART1
MP230H
ON
MEC120
MERT4
MEP230H
O
UVM5
MC120
MAUV1
MP560
ON
MEC120
MEUV4
MEP560
O
UVM6
MC120
MAUV1
MP560
See Note #B
MEC120
MEUV4
MEP560
C
- N/A — Not Applicable
- Programmer Dipswitches apply to MP230H, and MP560 only.
- Dipswitch #8 sets Recycle / Non-Recycle Operation.
- MP560 Programmer Module has "Check-Run" Switch.
- Note #A: For Standing Pilot, clip out red jumper on MP100.
- Note #B: Dipswitch #8 ON when red jumper of UVM6 is clipped.
bulletin:
C-4000
- N/A — Not Applicable
- Programmer Dipswitches apply to MEP200, and MEP500 Series Programmers
- Dipswitch #6 sets Recycle / Non-Recycle Operation. (O = Non-Recycle, C = Recycle)
- MEP500 Series Programmer Module has "Check-Run" Switch.
bulletin:
MC-5000
Notes for Cross Reference Table
1.
Requires new wiring base 60-1466-2 or 60-1386-2.
2.
Re-use existing scanner.
3.
Add timer if terminal 10 is used for open damper (30 seconds I.C.T.O).
4.
Make earth ground connection.
5.
E100 requires terminal 13 to be powered on call for heat. If there is no fuel valve end switch, make sure terminal 13 is powered from terminal 3.
6.
Refer to bulletin C-500 for starting circuit change.
7.
Replace scanner.
8.
Check ignition timing and select appropriate programmer (EP261 if Terminal 5 is used).
9.
Check if early spark termination is used, select appropriate programmer with same function.
10.
Requires new scanner with UV Self-check (45UV5-1000). A 6-conductor scanner cable (59-470) or run 4th lead for shutter is also needed.
11.
Use 60-2060-16 modernization adapter or hard-wire new wiring base 60-2206-1.
12.
Use 25SU5-5012 in multi-burner applications.
13.
Re-use existing scanner (45UV5-1005) if 60-2060-15 Adapter Base is used. If re-wiring to a new base (60-1386-2 or 60-1466-2), replace scanner with 45UV5-1009.
14.
Evaluate condition of existing wiring base and scanner. If it is appropriate, then hard-wire in a new base and replace the entire scanner assembly.
15.
Check the operating voltage of the existing system. The new control is only available in 120VAC.
16.
Evaluate modulating circuit, rewire as required.
17.
Evaluate dual scanner application. If possible, use one scanner (D-Series will not work with dual scanners).
18.
Supply new wiring base (60-1386-2 or 60-1466-2) and new scanner and rewire.
19.
Special for Babcock and Wilcox, original drawings need to be evaluated and updated as required.
20.
If terminals 5 and 6 are used, refer to Bulletin PD-4 page 2, note 2 for instructions to add external relay and use of 51CQ1 start pushbutton.
21.
Determine if a flame rod is being used and select an appropriate amplifier. If both a flame rod and an IR scanner are used, either one or the other must be disconnected or a second control and amplifier must be supplied.
22.
Refer to SN #47 to add relay for circulating fan motor.
23.
Refer to Bulletin C-4000 for appropriate dipswitch settings.
24.
The original UVM-1 control was supplied with a 24V (T and T) connection. If the low voltage circuit is used, then supply a transformer relay. A new wiring base is required.
25.
All M-Series controls are interchangeable without wiring changes except UVM1 and UVM2A.
26.
If the fuel valve end switch is not present, jumper terminals 3 to 13.
27.
Refer to Service Note #65.