| Featured Interface Solutions |
| Model |
Input |
Output |
Power |
Mounting |
|
HIM HART® Interface Module
|
Accepts and "Reads" the HART Digital Protocol Signal that Rides on the 4-20mA Wires of a Smart HART Multivariable Transmitter or Valve
|
"Break Out" Analog Signals Representing the Multivariable Transmitter's Primary, Second, Third or Fourth Variables, or Smart Valve Position and Status Parameters
Two or three 4-20mA Signals
Optional Dual Relay Outputs Warn of Unwanted Process Conditions or Diagnostic Problems
High/Low Alarms
(Failsafe or Non-Failsafe)
Two Redundant MODBUS RTU (RS-485) Data Links
Digital Display Shows Process Status and Fault Messages
|
24Vdc
|
High-Density and RFI Resistant
Aluminum DIN-style (G-type and Top Hat rails)
|
|
HCS HART® Concentrator System HART-to-MODBUS Converter
|
Accepts and "Reads" the HART Digital Protocol Signal that Rides on the 4-20mA Wires of a Smart HART Multivariable Transmitter or Valve
|
Converts the HART Digital Signal to serial (RS-485) MODBUS RTU Communication Protocol to allow smart transmitters and valves to interface with MODBUS-based systems.
|
4-Wire,
Line-Powered
(24Vdc)
|
High-Density and RFI Resistant
Aluminum DIN-style (G-type and Top Hat rails)
|
|
SPA 4-Wire Site-Programmable HART Loop Monitor and Alarm
|
Monitor a Process Variable and "Health" of a HART Transmitter or Valve
Accepts a HART digital input from a pressure, temperature, level, flow or multivariable transmitter or from a smart HART valve.
|
Dual Relays
Quadruple Relays
Selectable with On-Board Controls
High Alarm
Low Alarm
Failsafe
Non-Failsafe
Normally Open
Normally Closed
Latching
Non-Latching
HART Fault Alarm
Analog Output
Proportional to transmitter measurement, any multivariable transmitter measurement or valve stem position
|
Takes Any Power Supply
4-Wire, Universal Powered
(accepts 22-300Vdc or 90-260Vac)
CE approved unit comes with a 24Vdc, 117Vac or 230Vac power supply.
|
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
|
|
HFA 4-Wire HART Fault® Alarm
|
Monitor the "Health" of a HART Instrument
Accepts a HART digital input from a temperature, pressure, level, flow or multivariable transmitter.
|
Single-Pole/Double Throw HART Fault Alarm
High Alarm
Low Alarm
Failsafe
Non-Failsafe
Latching
Non-Latching
|
4-Wire,
Line-Powered
(18-30Vdc)
|
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
|
|
HIT and HIX 2- and 4-Wire HART® Isolators
|
4-20mA
input with superimposed HART digital protocol signal
|
Isolates Loop, Lets HART Digital Signal "Pass Through"
4-20mA
output with superimposed HART digital protocol signal
|
HIT
4-wire line-powered
(24Vdc, 117Vac, 230Vac)
HIX
2-wire loop-powered
(12-42DC)
|
Thermoplastic DIN-style
(G-type and Top Hat rails)
|
THZ & TDZ Isolated 2-Wire Smart HART Temperature Transmitters

|
Programmable via HART Communicator or Intelligent PC Software with HelpMap
RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel
Thermocouple
J, K, E, T, R, S, N, C, B
Ohms
0 to 4000 ohms
Millivolts
-50 to 1000mV
|
Standard, Easy-to-Read Process Displays
4-20mA output with superimposed HART digital protocol signal
|
2-Wire,
Loop Powered
(12-42Vdc or 12-28Vdc for IS applications)
|
NEW Field-Mount Dual-Compartment and Hockey-Puck with Complete Temperature Assemblies
(head, pipe, relay-track, surface and explosion-proof)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
|